Total hip arthroplasty for primary osteoarthroses in younger patients in the Finnish arthroplasty register
BW Schreurs and JWM Gardeniers
2005
Acta Orthopaedica, 76:4, 604-607
Open
Seppo Santavirta 1945–2005
Yrjö T. Konttinen
2005
Acta Orthopaedica, 76:5, 611-612
Open
Biotribology
Seppo Santavirta
2005
Acta Orthopaedica, 76:5, 613
Open
Limited influence of prosthetic position on aseptic loosening of elbow replacements
Joris C T van der Lugt, Ronald B Geskus & Piet M Rozing
2005
Acta Orthopaedica, 76:5, 654-661
Open
Cement-implant interface gaps explain the poor results of CMW3 for femoral stem fixation
Amos Race, Mark A Miller, Michael T Clarke & Kenneth A Mann
2005
Acta Orthopaedica, 76:5, 679-687
Open
Oxford medial unicompartmental arthroplasty for focal spontaneous osteonecrosis of the knee
Andrew J Langdown, Hemant Pandit, Andrew J Price, Christopher A F Dodd, David W Murray, Ulf C G Svärd & Christopher L M H Gibbons
2005
Acta Orthopaedica, 76:5, 688-692
Open
Controversies in knee surgery
Rien P. Heijboer
2005
Acta Orthopaedica, 76:5, 730
Open
Fixation of the cemented acetabular component in hip arthroplasty
Gunnar Flivik
2005
Acta Orthopaedica, 76:sup316, 1-30
Open
New polymer materials in total hip arthroplasty
Georgios Digas
2005
Acta Orthopaedica, 76:sup315, 4-82
Open
Postoperative Cox inhibitors and late prosthetic loosening—suspicion increases!
Per Aspenberg
2005
Acta Orthopaedica, 76:6, 733-734
Open
Do non-steroidal anti-inflammatory drugs cause endoprosthetic loosening? A 10-year follow-up of a randomized trial on ibuprofen for prevention of heterotopic ossification after hip arthroplasty
Per-Erik Persson, Olle S Nilsson & Ann-Marie Berggren
2005
Acta Orthopaedica, 76:6, 735-740
Open
Removal or retention—will we ever know? The posterior cruciate ligament in total knee replacement
Johan Kärrholm & Tuuli Saari
2005
Open
Retention versus removal of the posterior cruciate ligament in total knee replacement: A systematic literature review within the Cochrane framework
Wilco C H Jacobs, Darren J Clement & Ate B Wymenga
2005
Acta Orthopaedica, 76:6, 757-768
Open
All-polyethylene vs. metal-backed tibial component in total knee arthroplasty—a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: Part 1. Horizontally cemented components: AP better fixated than MB
Hans Hyldahl, Lars Regnér, Lars Carlsson, Johan Kärrholm & Lars Weidenhielm
2005
Acta Orthopaedica, 76:6, 769-777
Open
All-polyethylene vs. metal-backed tibial component in total knee arthroplasty—a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: Part 2. Completely cemented components: MB not superior to AP components
Hans Hyldahl, Lars Regnér, Lars Carlsson, Johan Kärrholm & Lars Weidenhielm
2005
Acta Orthopaedica, 76:6, 778-784
Open
Revision in previously satisfied knee arthroplasty patients is the result of their call on the physician, not on pre-planned follow-up: A retrospective study of 181 patients who underwent revision within 2 years
Ann B Bremander, Michael Dunbar, Kaj Knutson, Ingemar F Petersson & Otto Robertsson
2005
Acta Orthopaedica, 76:6, 785-790
Open
Measurement of bone mineral density is possible with standard radiographs: A study involving total knee replacement
Daniel Hernandez-vaquero, Manuel Angel Garcia-Sandoval, Jose Manuel Fernandez-Carreira, Abelardo Suarez-Vázquez & Domingo Perez-Hernández
2005
Acta Orthopaedica, 76:6, 791-795
Open
Comparison of distribution, agreement and correlation between the original and modified Merle d’Aubigné-Postel Score and the Harris Hip Score after acetabular fracture treatment: Moderate agreement, high ceiling effect and excellent correlation in 450 patients
Stein Øvre, Leiv Sandvik, Jan Erik Madsen & Olav Røise
2005
Acta Orthopaedica, 76:6, 796-802
Open
Staged bilateral total hip arthroplasty using rough and smooth surface femoral stems with similar design: 10-year survivorship of 48 cases
Sandeep P Datir & Charles H Wynn-Jones
2005
Acta Orthopaedica, 76:6, 809-814
Open
Regional variation in incidence of primary total hip arthroplasties and revisions in Denmark, 1996–2002
Alma B Pedersen, Søren P Johnsen, Søren Overgaard, Kjeld Søballe, Henrik T Sørensen & Ulf Lucht
2005
Acta Orthopaedica, 76:6, 815-822
Open
Validation of data in the Norwegian Arthroplasty Register and the Norwegian Patient Register : 5,134 primary total hip arthroplasties and revisions operated at a single hospital between 1987 and 2003
Astvaldur J Arthursson, Ove Furnes, Birgitte Espehaug, Leif I Havelin & Jon A Söreide
2005
Acta Orthopaedica, 76:6, 823-828
Open
Tranexamic acid reduces blood loss in cemented hip arthroplasty: A randomized, double-blind study of 39 patients with osteoarthritis
Raimo O Niskanen & Olli L Korkala
2005
Acta Orthopaedica, 76:6, 829-832
Open
The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: Spatial orientation of the pelvis in different positions
Eckart Mayr, Oliver Kessler, Alexandra Prassl, Franz Rachbauer, Martin Krismer & Michael Nogler
2005
Acta Orthopaedica, 76:6, 848-853
Open
Treatment of sequelae of radial head fractures with a bipolar radial head prosthesis: Good outcome after 1–4 years follow-up in 11 patients
Justus-Martyn Brinkman, Frank Th G Rahusen, Maarten J de Vos & Denise Eygendaal
2005
Acta Orthopaedica, 76:6, 867-872
Open
No adverse effects of bone compaction on implant fixation after resorption of compacted bone in dogs
Background A new bone preparation technique, compaction, has been shown to enhance initial implant fixation. However, short-term compaction has resulted in more non-vital bone being in contact with the implant. Also, compaction may result in inferior long-term implant fixation as the compacted non-vital bone at the bone-implant interface is resorbed. Methods We tested the hypothesis that compaction would result in inferior implant fixation after 10 weeks of weight bearing. We compared compaction with the conventional bone removal technique (drilling) for (1) porous coated titanium (Ti) implants inserted exact-fit into medial femoral condyles, and for (2) hydroxy-apa-tite (HA) porous coated implants inserted press-fit into lateral femoral condyles. In each of 8 dogs, we prepared the implant cavities of one knee joint with drilling, and the other with compaction. Implants were tested mechanically to failure by push-out test, and histomor-phometry was done. Results For all specimens, non-vital bone implant contact contributed very little to the total bone implant contact. Inferior mechanical or histological implant fixation with compaction was not found for either Ti implants or HA implants. Interpretation Compaction does not appear to result in inferior implant fixation as the compacted bone at the bone implant interface is resorbed.
2005
Acta Orthopaedica, 76:6, 912-919
Open